CONNECTION
| INPUT | WIRING | |
| METOS 5 and µMETOS | ||
| UART (29-0423 variant) PIB-2/RS485 (29-0426 variant) | 29-0423: PW: Brown RX: Green WH: White 29-0426: BR: Brown GR: Green WH: White | ![]() |
| SENS-X (all variants) | PW: Brown DT: Green GN: White | ![]() |
| METOS 5 Only | ||
| USWS (29-0423 variant) DC/PIB-3/UART (29-0426 variant) | NA | ![]() |
| iMETOS 3.3 | ||
| INPUT 1-4 | NA | ![]() |
➡️ If USWS (METOS 5 29-0423 variant) or DC/PIB-3/UART ( METOS 5 29-0426 variant) is currently in use by another sensor; you may remove the Pancon connector and hard-wire the sensor to the other inputs mentioned above.
INSTALLATION (In Progress)
PI wind direction sensors are factory‑calibrated, and no user action is required. However, it is recommended that the attachment of the vane, followed by the installation of the sensor on the post, should be as shown in the image below:

- If you wish or need to calibrate the sensor, the METOS 5 and μMETOS devices provide an additional calibration function described in one of the manuals in the attachment below.
⚠️ iMETOS 3.3 DOES NOT SUPPORT calibration. For installation, refer to the above image only.
⚠️ Direction wind sensors must be aligned with true north (geographic north).